PBU 500 MPI BENCH - TECHNICAL SPECIFICATION

Max Testpiece Length 500mm
Max Testpiece Weight 7.5Kg
 

STANDARD FEATURES

OPTIONAL FEATURES

Power Pack AC and HWDC waveform.  
Current Flow Magnetising Max output nominally 1400A peak.  
Encircling Coil Magnetising   150mm ID coil clamped between head and tail stocks.
Flux Flow Magnetising   Flux coils mounted on head and tail stocks.
Current Control System Thyristor current control via front panel knob.  
Working Range 10% to 100% of maximum output.  
Metering Digital, displayed as peak. Accuracy is better than ±5% over the working range.  
Shot Time A single preset shot of 1, 2 or 3 seconds. Operator selectable.
Duty Cycle Dynamic duty cycle from 20% at max output to 100% at approx 400A.  
Max ON Time 3 seconds at 20% duty cycle.  
Demagnetising Automatic decaying AC.  
Headstock Spring loaded clamping system. 50mm diameter contact pads with 360° rotation.   
Tailstock Fully adjustable over bed length.  
Inking System Aerosols and Polyspray. Optional free standing pumped ink recirculation system.
    Power Supply 230V/115V single phase AC, 50/60Hz, 13A.  
    Air Supply Not required.  