EBU SERIES MPI BENCH - TECHNICAL SPECIFICATION

 

EBU 1000

EBU 1500

EBU 2000

EBU 2500

Max Testpiece Length 1000mm 1500mm 2000mm 2500mm
Max Testpiece Weight 250Kg 250Kg 250Kg 250Kg
Dimensions (mm) 2000W x 850D  2500W x 850D 3000W x 850D 3500W x 850D
Height to bed bar 885mm 885mm 885mm 855mm
Bed to pad centre 430mm 430mm 430mm 430mm
 

STANDARD MODELS

OPTIONS AND ALTERNATIVES

Power Pack AC waveform with rated output currents as follows: 3 Series - 4200A peak, 5 Series - 7000A peak for duty cycles as below . HWDC and single or 3-phase FWDC waveforms. Alternative outputs on request.
Current Flow Magnetising Nominal max output: 3 Series - 4200A peak, 5 Series - 7000A peak measured through a standard shunt. Nominal max output: HWDC: 3 Series - 4200A peak, 5 Series - 7000A peak measured through a standard shunt.
Encircling Coil Magnetising Carriage mounted, 5 turn, 300mm ID, length 120mm.Nominal max output/centre field strength in an empty coil; 3-Series -  10000AT AC peak / 34KA/m, 5 Series - 18000AT AC peak / 47KA/m.  Interchangeable alternative sizes: 400, 400 and 600 mm ID.
Flux Flow Magnetising   Head and tailstock flux coils with laminated steel cores powered by AC, HWDC, or single or 3-phase FWDC.
Multi-Directional Magnetising   Simultaneous operation of two magnetising circuits, to produce a swinging field.
Current Control System Variable thyristor with resulting complex waveform. Variable transformer with resulting sinusoidal waveform.
Working Range 10% to 100% of maximum output. Extended working range subject to requirements.
Metering Digital on all models. Currents displayed in peak. Accuracy is better than ±5%. AC displayed as rms (sinusoidal only). HWDC and FWDC output displayed as peak.
Shot Time  A preset single shot of 1, 2 or 3 seconds. Operator selectable from three preset shot times, plus special requirements.
Duty Cycle Dynamic duty cycle from 20% at max output to 100% at approx 1000A.  
Max ON Time 3 seconds at 20% duty cycle.  
Demagnetising Automatic decaying AC. Manually selectable demag starting level. Low frequency switched polarity stepdown, suited for FWDC magnetising.
Headstock Pneumatically operated via footswitch control. 160 x 160mm contact pads with V-block supports. 50mm maximum clamping travel. Adjustable clamping pressure. Foot-switch operated clamping. Alternative clamping travel.
Tailstock Fully adjustable over bed length, bearing mounted, with V-block supports. Manual quick release lock. Motorised positioning.
Testpiece Support Removable V-blocks on head and tailstocks. Integrally mounted roller supports. Detachable small piece device for protection of delicate testpieces. Bed bar mounted adjustable support.
Inking System 50 litre stainless steel covered reservoir with recirculating pump, manual application and integral controls. Automatic inking as part of the automated process sequence.
Services    
    Power Supply 380/415V 3-phase AC + neutral + earth, 50/60Hz. Current drawn approx 3-Series - 150A, 5-Series - 230A. The multi-directional magnetising option requires a 415V 3-phase AC + neutral + earth, 50/60Hz. Current drawn 65A max.
    Air Supply 6 bar (FR unit fitted as standard)  

Baugh & Weedon NDT has a policy of continuous improvement, thus this specification may change.



Baugh & Weedon Ltd. is a Minton, Treharne and Davies Ltd. Group Company
Baugh and Weedon Ltd. Beech Business Park, Tillington Road, Hereford, HR4 9QJ
Telephone 01432 267671 • Fax 01432 359017 • email sales@bandwndt.co.uk